JDZ(X)R8-10A,B,C Voltage transformer from JUCRO Electric
JDZ(X)R8-10A,B,C Voltage transformer from JUCRO Electric
JDZ(X)R8-10A,B,C Voltage transformer from JUCRO Electric
JDZ(X)R8-10A,B,C Voltage transformer from JUCRO Electric
JDZ(X)R8-10A,B,C Voltage transformer from JUCRO Electric
JDZ(X)R8-10A,B,C Voltage transformer from JUCRO Electric
Model
JDZ(X)R8-10A,B,C

Review

Description

JDZ(X)R8-10A,B,C  Voltage transformer from JUCRO Electric

Description


The voltage transformers of the types RZL(JDZ)10-3,6,10A(B) are single phase, casting resin insulated and full enclosed products. They are used for metering electric energy, voltage control and relay protection in the electric non-useful-ground neutral system up to rated frequency 50Hz or 60Hz and rated voltage 10kV. The transformers can be executed according to the standards IEC186 and GB1207-1997.

Type description

Construction

 The type of voltage transformer have much merit, such as: electric arc resistance, ultraviolet ray and aging resistance, long creepage distance, little partial discharge and large caliber of resistance to over-voltage. The primary of the products are protected with fused. The fused is installed inside the transformer. The fusible cutout’s fused current can match the transformers short-circuit force. When the electrified wine netting breakdown, the fused can protect the transformer not breaker.



Technical data 

1.        Technical data form;

2.        The fusible cutout’s type: JDZR8-10ABCXRNP-120.2A50KA. JDZR8-10ABC: JDZR8-10ABCXRNP-12 type, 0.20.5(If special need, please notice when order);

3.        If being requested to connect the computer, the secondary load of class 0.2 or 0.5 class can up to 1VA.

  

Technical data
type

Rated voltage ratio(V)

Rated output(VA)

Limit output(VA)

Insulated level(kV)

0.2
0.5
1
6P
JDZR8-10A
3000/100
15
30
60

300

15

3.6/25/40

6000/100
7.2/32/60
10000/100
12/42/75
JDZXR8-10A
3000/2sin60°/100/2sin60°/100/3
15
30
60
50
300
3.6/25/40
6000/2sin60°/100/2sin60°/100/3
7.2/32/60
10000/2sin60°/100/2sin60°/100/3
12/42/75
type
Rated voltage ratio(V)
Accuracy class

Rated output(VA)

Limit output(VA)
Insulated level(kV)
JDZR8-10B
3000/100
0.2
30
500
3.6/25/40
6000/100
0.5
50
7.2/32/60
10000/100
1
90
12/42/75
3000/100/100
0.2/0.2
15/15
2×250
3.6/25/40
6000/100/100
0.2/0.5
15/30
7.2/32/60
10000/100/100
0.5/0.5
30/30
12/42/75

JDZXR8-10B

JDZXR8-10BG
3000/2sin60°/100/2sin60°/100/3

0.2/6P

0.5/6P




25/50

50/50
400
3.6/25/40
6000/2sin60°/100/2sin60°/100/3
7.2/32/60
10000/2sin60°/100/2sin60°/100/3
12/42/75

JDZXR8-10B

3000/2sin60°/100/2sin60°/100/3

0.2/0.2/6P

0.2/0.5/6P

0.5/0.5/6P



15/15/50

15/20/50

20/20/50
2×200
3.6/25/40
6000/2sin60°/100/2sin60°/100/3
7.2/32/60
10000/2sin60°/100/2sin60°/100/3
12/42/75
type
Rated voltage ratio(V)

Rated output(VA)

Limit output(VA)
Insulated level(kV)
0.2
0.5
1
JDZR8-10C
3000/100
30
80
150
500
3.6/25/40
JDZR8-6C
6000/100
7.2/32/60
JDZR8-10C
10000/100
12/42/75
 Packing & Delivery 

Strong package, Safety first.

Inside with foam to support the product, put it in carton or wooden box, fixed it on pallet.

As long as possible to keep the products safe until it arriving customer's warehouse.

Clearly marking label outside of package, customers will be easy to identify their goods.
Our Company
20000 M2 of JUCRO Electric company land

1500 M2 of office building

5000 M2 of workshop building

Vacuum Interrupter Workshop

Accept customized order.
Design the Vacuum Interrupter for you.

VCB Production Line

VCB Vacuum Circuit Breaker production Line.

VCB Production Line

VCB Vacuum Circuit Breaker production line, Engineers routine inspection.
Quality Inspection

Carefully inspection of each product, Quality guaranteed 

 completely data records of entire process , all the product data can be traced.