Circuit Breaker HVD8 40.5KV 2000A SF6 from JUCRO Electric
- Model
- HVD8-40.5/2000
Review
Description
a.
The circuit breaker is outdoor small ceramic column structure, which
equipped with CT14 spring operation mechanism; mechanism and
main part connected with simple installation. It has features of convenient adjustment, reliable operation, suitable for
frequent operation; mechanism service life more than 3000 times;
b. Adopt air-compression arc-extinguishing structure, with strong breaking
capacity, 40kA total breaking times up to 12, which is the highest in China:
c.
Reliable sealing performance. Adopt import seal;
dynamic seal adopts "V" type sealing ring with spring pressure compensation structure; the transformer
secondary wiring board matched by cooperative enterprises,
to ensure the annual leakage rate less than 1%,
d. Inner current transformer adopts micro crystallizing alloy high magnetic
materials, with accurate class up to grade 0. 2 or grade 0.2S. According to
users' needs, it can be matched with 12 transformers, to meet the load line of
50 km without restrike.
Item |
Unit |
Date |
|
Rated voltage |
KV |
40.5 |
|
Rated insulation level |
Lightning impulse withstand voltage(peak value) |
KV |
185 |
1min power frequency withstand voltage | KV | 95 | |
Rated current | A | 2000 | |
Mechanical life time | time | 3000 | |
Rated air pressure of SF6
(psig at 20℃) | Mpa | 0.05 | |
Alarm pressure/Min function
pressure (psig at 20℃) | Mpa | 0.47/0.45 | |
Rated
short-circuit breaking current | KA | 40 | |
Rated short
circuit making current (peak value) | 100 | ||
Rated short time withstand
current (thermal stability current) | 40 | ||
Rated peak withstand
current (dynamic stability current) | KA | 100 | |
Rated out of step breaking
current | KA | 10 | |
Rated breaking times under
short circuit breaking current | time | 12 | |
Rated short circuit
duration | S | 4 | |
Closing time (under rated
operation voltage) | S | ≤0.1 | |
Opening time (under rated
operation voltage) | S | ≤0.06 | |
Rated operating sequence | O-0.3s-CO-180s-CO | ||
Rated making
single capacitor bank current | A | 400 | |
Annual leakage
rate | % | ≤1 | |
SF6 water content(V/V) | ≤150*10-6 | ||
Rated operation voltage of matched
CT14 spring operation mechanism | |||
Closing and opening coil voltage | V | AC: 220 380 DC: 18 110 220 | |
Energy storage motor
voltage | V | AC: 220 380 DC: 110 220 | |
Weight of SF6 gas | kg | 8 | |
Weight of circuit breaker (including
operation mechanism) |
kg |
1400 |
Item |
Unit |
Data |
Technical parameter |
Moving contact
travel | mm | 95±2 | Measure moving contact
travel |
Opening distance
between contacts | mm | 60±1.5 | Measure
distance between moving and fixed contact |
Pole-to-pole closing
synchronous | ms | ≤3 | Measure pole distance
difference between moving and fixed contact |
Pole-to-pole opening
synchronous | ms | ≤2 | Measure pole
distance difference between moving and fixed contact |
Main circuit resistance | mΩ | ≤120 | Measure DC
voltage reduction |
Closing speed |
m/s |
3.2±0.2 |
Rated air
pressure, measuring method |
Opening speed |
m/s |
3.4±0.2 |
Rated air
pressure, measuring method |
Closing buffer distance |
mm |
9.5-11 |
Under closing
state |
Spacer of closing buffer | mm | 1-2 | Under closing
state |
Partial 48.6kV | Pc | 20 | Measure by partial
measuring device under rated air pressure; apply voltage 486kv on the two
out-line ends of the circuit breaker for 1 min, then reduce the voltage to 28V
to measure |
Disharge 28kV | Pc | 10 |