Disconnecting Switch GW5 series outdoor HV From Jucro Electric
Disconnecting Switch GW5 series outdoor HV From Jucro Electric
Disconnecting Switch GW5 series outdoor HV From Jucro Electric
Disconnecting Switch GW5 series outdoor HV From Jucro Electric
Disconnecting Switch GW5 series outdoor HV From Jucro Electric
Disconnecting Switch GW5 series outdoor HV From Jucro Electric
Model
GW5

Review

Description

GW5 series outdoor HV disconnecting switch From Jucro Electric
    GW5 series outdoor isolating switch is one of the most commonly used equipment in the power system, the main role is to high voltage isolation in equipment or line maintenance, to ensure the safety of. It should not disconnect the load current and short-circuit current, should be used in conjunction with the circuit breaker, the first branch circuit breaker in power after the isolation switch, power supply first combined together after the circuit breaker switch.
    Genus of double column type V level open type GW5 series outdoor isolating switch, each single comprises a base, a supporting insulator, outlet and the contact part, is composed of two support to 50°,two pillar porcelain insulator on both ends of the angle between the base and the base bearing, vertical. Main electrical parts are installed on the two pillar porcelain insulated bottle top, with the pillar insulated bottle of about 90°rotation
Outline and mounting dimension 

The main parameters 

Item

Unit

Parameters

 Rated voltage

KV

40.5

72.5

126

Rated insulation level

1min power frequency withstand voltage(effective value)

On the groud

KV

95

160

230

Fracture

KV

118

200

230+70

Rated lightning impluse
withstand current(peak)

 On the groud

KV

185

350

550

Fracture

KV

215

410

550+110

Rated Frequency

Hz

50/60

Rated Current

A

630

1250

1600

2000

2500

Rated short-time withstand current

KA

20

31.5

40

40

40

 Rated peak withstand current

KA

50

80

100
100

100

Rated short circuit duration

Knife/Sword

S

4/4

4/4

4/4

Rated mechanical terminal load

Horizontal and vertical

N

750

1000

1000

Horizontal

N

500

750

750

 vertical force

N

750

1000

1000

 Creepage distance

mm

1013
1250


1813
2248

3150
3906

RIV Five wire electric interference level

μV

≤500

 Mechanical life

Times

5000

Motor actuator

 Model


CJ

Motor voltage

V

AC380、AC220、DC220、DC110

 Voltage control loop

V

AC380、AC220、DC220、DC110

Points,closing times

S

7±1

Human actuator

Model

CS17

Electromagnetic lock voltage

V

AC220、DC220、DC110

 Packing & Delivery 

Strong package, Safety first.

Inside with foam to support the product, put it in carton or wooden box, fixed it on pallet.

As long as possible to keep the products safe until it arriving customer's warehouse.

Clearly marking label outside of package, customers will be easy to identify their goods.
Our Company
20000 M2 of JUCRO Electric company land

1500 M2 of office building

5000 M2 of workshop building

Vacuum Interrupter Workshop

Accept customized order.
Design the Vacuum Interrupter for you.

VCB Production Line

VCB Vacuum Circuit Breaker production Line.

VCB Production Line

VCB Vacuum Circuit Breaker production line, Engineers routine inspection.
Quality Inspection

Carefully inspection of each product, Quality guaranteed 

 completely data records of entire process , all the product data can be traced.